Navien
Navien Error Codes
Find troubleshooting guides for all Navien error codes.
10 error codes across 1 appliance types
Waterheater
View all 10 codes →
Code
Meaning
Severity
E001
The unit failed to establish a flame on the first ignition attempt. E001 is an early-stage ignition fault that precedes E003, which fires after all 3 attempts fail.
high
high
E003
After three ignition attempts with no flame signal detected, the PCB shuts down the sequence and throws a lockout. The gas valve, spark igniter, and flame rod sensor all have to work together at exactly the same moment for a successful light-off. Any one of them failing breaks the whole chain.
high
high
E012
The burner flame lit up fine but went out while the unit was actively heating water. It's different from E003, which means ignition never happened at all. This one means you had a flame, lost it, and the rod stopped seeing the ionization signal it needs to keep the valve open.
high
high
E110
The differential pressure switch detected that air isn't moving through the exhaust and intake pathways correctly. Either the path is physically blocked, or the pressure drop across the vent system is outside the range the switch is calibrated to accept.
high
high
E302
The control board is picking up a flame signal from the flame rod even though the gas valve is closed and nothing should be burning. It's a safety lockout. The board won't let the unit run again until that false signal clears.
moderate
moderate
E762
The outlet water temperature exceeded 190 degrees Fahrenheit (87.7 degrees Celsius), triggering a high-limit safety lockout. The unit shuts off to prevent scalding and thermal damage to components.
high
high
E773
The exhaust gas temperature exceeded the safe thermal limit. A thermal fuse or high-limit sensor in the exhaust path tripped due to excessive heat, causing a safety lockout.
high
high
HUB
Your Navien detected a fault condition and locked out to protect itself. The letter-number code on the display tells you exactly which system tripped. Each code maps to a specific sensor, circuit, or mechanical failure point inside the unit, so the display is basically the unit telling you where to look.
low
low
NO-HOT-WATER
The control board detected a condition that prevents safe firing. Could be insufficient water flow through the heat exchanger, a failed ignition sequence, or a backed-up condensate drain tripping the safety float switch. The unit shuts itself down to prevent damage.
moderate
moderate
RESET
Guide covering all three reset methods for Navien NPE and NCB series: soft reset via Info button, hard reset via power cycle, and factory reset via controller menu.
low
low