Skip to main content
Warning: Disconnect power before servicing.
|
Verified technical guides
|
1,100+ Error Codes Decoded
ErrBase
Brands
Error Codes
OEM Parts
Home
/
Rinnai
Rinnai Error Codes
Find troubleshooting guides for all Rinnai error codes.
16 error codes across 1 appliance types
Waterheater
View all 16 codes →
Code
Meaning
Severity
10
The unit detected that no gas was available or the gas valve was unable to open when a heating demand was made.
high
high
11
The unit attempted to ignite 3 times and no flame was detected by the flame rod. The burner has locked out as a safety measure.
high
high
12
The burner successfully ignited but the flame extinguished unexpectedly during a heating cycle. The unit shut down to prevent unsafe operation.
high
high
14
The one-time thermal fuse (thermal cutoff) protecting the heat exchanger has blown, indicating the exchanger reached a dangerously high temperature. The unit is locked out until the fuse is replaced.
critical
critical
15
The burner has been locked out following an abnormal combustion sequence during ignition. The unit detected an irregularity during the ignition attempt and shut down as a safety measure.
high
high
17
The gas valve was unable to modulate or operate correctly as commanded by the control board. An abnormal voltage or position was detected during the heating cycle.
high
high
25
The bath fill sequence did not complete within the programmed time limit. This code only appears on Rinnai models equipped with the built-in bath fill or ThermaCirc recirculation feature.
low
low
32
The outlet water temperature sensor detected that the water leaving the heat exchanger exceeded the maximum safe limit. The unit shut down to prevent scalding or heat exchanger damage.
high
high
52
The modulating gas valve was unable to reach or hold the target firing position commanded by the PCB. The valve's modulation mechanism has failed to operate correctly.
high
high
55
The unit detected combustion that is outside normal operating parameters. This can mean incomplete combustion, combustion instability, or an air-to-fuel ratio that the sensors have flagged as abnormal.
high
high
61
The combustion fan motor has failed to start or stopped operating completely. The unit cannot initiate or sustain a heating cycle without a functioning blower.
high
high
63
The combustion fan (blower) did not reach the required speed within the expected time, or the fan speed sensor reported an abnormal reading during startup or operation.
high
high
79
The sensor measuring the temperature of combustion air entering the unit has failed or is reading outside its expected range.
moderate
moderate
HUB
Reference hub covering all Rinnai RU and V series tankless water heater error codes with diagnosis and repair guidance.
low
low
NO-HOT-WATER
Error Code, Flow, and Flame Fixes
medium
medium
RESET
Step-by-step instructions for performing soft, hard, and factory resets on Rinnai tankless water heaters to clear error codes and restore normal operation.
low
low