Code
Meaning
Severity
10
The unit detected that no gas was available or the gas valve was unable to open when a heating demand was made.
high
high
11
The unit attempted to ignite 3 times and no flame was detected by the flame rod. The burner has locked out as a safety measure.
high
high
12
The burner successfully ignited but the flame extinguished unexpectedly during a heating cycle. The unit shut down to prevent unsafe operation.
high
high
14
The one-time thermal fuse (thermal cutoff) protecting the heat exchanger has blown, indicating the exchanger reached a dangerously high temperature. The unit is locked out until the fuse is replaced.
critical
critical
15
The burner has been locked out following an abnormal combustion sequence during ignition. The unit detected an irregularity during the ignition attempt and shut down as a safety measure.
high
high
17
The gas valve was unable to modulate or operate correctly as commanded by the control board. An abnormal voltage or position was detected during the heating cycle.
high
high
25
The bath fill sequence did not complete within the programmed time limit. This code only appears on Rinnai models equipped with the built-in bath fill or ThermaCirc recirculation feature.
low
low
32
The outlet NTC sensor caught the water temp climbing past the safe limit and triggered a safety shutdown. It's protecting the heat exchanger from warping and preventing the thermal fuse from blowing, which would be a much worse and more expensive problem.
high
high
52
The modulating gas valve couldn't reach or hold the target firing position commanded by the PCB. Basically the valve's modulation mechanism failed to operate correctly, so the unit can't control flame height.
high
high
55
The unit detected combustion that's outside normal operating parameters. Could be incomplete combustion, instability in the flame, or an air-to-fuel ratio the sensors flagged as wrong. Basically the machine knows something's off with how it's burning and it's shutting itself down to keep you safe.
high
high
61
The combustion fan motor has failed to start or stopped operating completely. The unit cannot initiate or sustain a heating cycle without a functioning blower.
high
high
63
The combustion fan (blower) did not reach the required speed within the expected time, or the fan speed sensor reported an abnormal reading during startup or operation.
high
high
79
The sensor measuring the temperature of combustion air entering the unit has failed or is reading outside its expected range.
moderate
moderate
HUB
This is the reference hub for all Rinnai RU and V series error codes. When the unit detects a fault, it throws a two-digit number on the controller display and shuts down to protect itself. Each number maps to a specific sensor or system that's either failing or reading outside its normal range.
low
low
NO-HOT-WATER
The unit's control board triggered a safety shutdown because it detected a failure in ignition, flow, or venting. The burner assembly isn't firing, or it fires and cuts out immediately. That controller is reading sensor data in real time and killing the gas valve the moment something falls outside acceptable parameters.
moderate
moderate
RESET
Step-by-step instructions for performing soft, hard, and factory resets on Rinnai tankless water heaters to clear error codes and restore normal operation.
low
low